Technical tools for checking a solar design: inverter size, string length, charge controller rating, cable cross section and voltage drop.
Most popular
Design checks protect equipment and people. A string that is too long can exceed the inverter's maximum DC voltage on a cold morning, and an undersized cable wastes energy and can overheat. These calculators show each check against the limit so you can see how much margin you have.
They are planning aids, not a substitute for a competent designer. Fixed installations must be designed and installed by qualified people and, in the UK, meet BS 7671 and the relevant connection rules.
All solar system design calculators
More solar system design calculators
Guides on this topic
-

What Does a Solar Inverter Do? Types and Sizing Explained
How an inverter converts DC to AC, the main types, how they are sized and how long they last.
-

Solar Optimisers Explained: What They Do and When They Pay Back
How panel-level optimisers work, full versus selective fitting, and a payback test for any quote.
-

Microinverters vs String Inverters: Which Suits Your Roof?
Shading, batteries, G98 limits and a payback test for panel-level versus central solar inverters.
-

G98 vs G99: Which Grid Connection Route Does Your Solar or Battery Need?
The 16 A per phase rule in kW, which solar and battery set-ups need DNO approval, and what to ask.
-

Solar Inverter Lifespan: How Long Will Yours Last?
How long inverters last, what shortens their life and what replacements add to solar payback.
-

Series vs Parallel Solar Panels: Which Wiring Should You Use?
Voltage, current, shade and cable loss for series, parallel and 2S2P layouts, with a cold check.
-

MPPT vs PWM: Which Solar Charge Controller Do You Need?
How PWM and MPPT controllers differ, with a temperature table showing the real harvest gap.
-

Do You Need Planning Permission for Solar Panels? England Rules for 2026
England’s 2026 permitted development limits for solar on roofs, walls, gardens and plug-in kits.
-

MCS Certificate for Solar Panels: What It Proves and How to Get a Copy
What an MCS solar certificate proves, the fields to check, SEG rules and how to replace a lost one.
Frequently Asked Questions
How do I size a solar inverter?
For a grid-tied system, many designs use a DC to AC ratio between about 1.1 and 1.3, so a 5 kWp array often pairs with a 4 to 4.6 kW inverter. Off-grid inverters are sized for the largest continuous load plus motor start-up surges.
What voltage drop is acceptable?
UK guidance based on BS 7671 commonly uses 3% for lighting and 5% for other uses on a public supply, measured from the origin of the installation. Many solar designers aim for lower drops on DC cables to reduce losses.
Why does cold weather matter for string size?
Panel open-circuit voltage rises as temperature falls. On a cold, bright morning a long string can exceed the inverter or controller's maximum input voltage, so the maximum string length must be checked at the coldest expected temperature.
Checked October 2026 by the Solaxyra Editorial Team. Read how we build and check our tools in our editorial policy.