This guide answers, for UK homes with a gas boiler, a heat pump, storage heaters or electric heaters, whether running the heating constantly costs more or less than switching it on only when needed, and shows the numbers behind the answer. The question is it cheaper to leave heating on all day has a different answer for a boiler and for a heat pump, so it pays to know which you have.
Quick answer: Is it cheaper to leave heating on all day? Not with a gas or oil boiler. A home loses heat in proportion to how much warmer it is than outside, so letting it cool while you are out means less heat to replace. Heat pumps are the exception: the Energy Saving Trust says running them all day can save money.

Is it cheaper to leave heating on all day with a gas boiler?
No: with a boiler, keeping the heating on all the time uses more energy and costs more than heating the home only when you need it. That is the position of the Energy Saving Trust in its 2026 advice When should I put my heating on?, which says it is more energy efficient, and better for your bills, to have the boiler come on when you need it.
The same page gives the opposite answer for heat pumps, which work best when left running all day. So when someone asks “is it cheaper to leave heating on all day”, the honest reply starts with another question: what heats your home?
Why does switching the heating off save energy?
A house loses heat at a rate set by how much warmer it is inside than outside, so any hour spent at a lower indoor temperature loses less heat. The standard heat flow formula on thermal transmittance (U-value) makes this clear: heat flow in watts equals U-value × area × temperature difference.
Over a whole day, the heat your boiler supplies equals the heat the house loses, because the home ends the day at the same temperature it started. When the heating is off, the house cools, the temperature difference shrinks and heat escapes more slowly. The burst of heating needed to warm it up again only replaces the heat that actually escaped, which is less than a constantly warm house would have lost over the same hours.
The common belief behind “is it cheaper to leave heating on all day” is that the reheat costs more than the saving. The heat balance shows it cannot, as long as the system works about as efficiently in a reheat as when ticking over. A well insulated home cools slowly, so it saves less by switching off, but it still does not lose more. To see how quickly your own home loses heat, use the heat loss calculator.
How much does switching off for part of the day save?
To put a price on the question is it cheaper to leave heating on all day: in the example below, switching a gas heated home off for eight hours saves about 42p on a cold day, and a set-back temperature saves about 32p. Prices are Ofgem’s cap for 1 October to 31 December 2026, with gas at 7.97p per kWh, from the Ofgem price cap announcement.
Example: a home loses 150 W for every degree it is warmer than outside (an example value, change to yours). It is 5°C outside and the home is kept at 20°C when heated. During an eight-hour gap the home is assumed to drift down to an average of 16°C if switched off, or to hold 17°C on a set-back. The boiler is assumed to be 90% efficient.
| Pattern for one day | Heat lost (kWh) | Gas used at 90% (kWh) | Gas cost at 7.97p | Saving vs on all day |
|---|---|---|---|---|
| On all day at 20°C | 54.0 | 60.0 | £4.78 | n/a |
| Set-back to 17°C for 8 hours | 50.4 | 56.0 | £4.46 | 32p |
| Off for 8 hours (average 16°C) | 49.2 | 54.7 | £4.36 | 42p |
The heat lost is 150 W × temperature difference × hours. On all day: 150 × 15 × 24 = 54.0 kWh. Off for eight hours: 150 × (15 × 16 + 11 × 8) = 49.2 kWh. Over an example heating season of 150 such days, switching off would save about £64. The central heating cost per hour calculator shows what your own boiler costs to run.
Is it cheaper to leave heating on all day if you have a heat pump?
Yes, for most heat pumps: the Energy Saving Trust says it is best to keep a heat pump on all the time, using a lower set-back temperature when you are out or asleep. Its guide on how to make a heat pump run efficiently, updated 20 October 2026, says longer running periods do not raise overall running costs, because the system runs more efficiently.
A heat pump is most efficient when it makes cooler water, typically around 45°C according to the Energy Saving Trust, against about 75°C for a boiler. Switching it off and asking it to warm a cold house quickly pushes it towards hotter water and a lower efficiency, and may bring in the backup heater. Running steadily on a weather compensated heating curve keeps the efficiency high. The Energy Saving Trust also advises against heating hot water overnight unless you are on a time-of-use tariff. Check your figures with the heat pump COP calculator and the heat pump running cost calculator.
What about storage heaters, electric heaters and underfloor heating?
For direct electric heaters, switch off when not needed: every hour of a 2 kW heater costs 52.64p at the October 2026 cap, and like a boiler it gains nothing from running in an empty room. Storage heaters follow their own rule, charging on cheap night electricity and releasing heat through the day.
| Heating system | Leave on all day? | Better approach |
|---|---|---|
| Gas or oil boiler | No | Timer for when you are in; set-back or off when out or asleep |
| Heat pump | Yes, usually | Run continuously with a lower set-back temperature |
| Storage heaters | Charge at night | Set the input for the next day’s weather; see how to use storage heaters |
| Plug-in electric heaters | No | Heat only the occupied room, using the heater’s thermostat |
| Underfloor heating (wet, slow to respond) | Depends on the heat source | Use a modest set-back rather than full off, and start earlier |
Underfloor heating in a screed takes a long time to warm up, so a short gap may not let the floor cool much and a long warm-up period is needed afterwards. The physics still holds: a lower average temperature means less heat lost. A set-back temperature is usually the practical middle ground. The electric heater running cost calculator works out costs for plug-in heaters.
What is the best heating schedule for a boiler?
Set the heating to come on about half an hour before you get up and go off about half an hour before bed, with the thermostat between 18°C and 21°C, which is the Energy Saving Trust’s guidance. If you are out during the day, switch the heating off or use a set-back.
- Set the room thermostat to the lowest comfortable temperature, usually 18°C to 21°C; see what temperature to set your thermostat.
- Programme on periods for the times people are at home and awake.
- If your thermostat allows it, use a set-back of about 12°C to 15°C for nights and absences, as the Energy Saving Trust heating controls guide suggests.
- On very cold days bring the heating on earlier rather than turning the thermostat up; a higher setting does not heat the home faster.
- Set each radiator valve to the lowest setting that keeps that room comfortable, keeping some background heat to limit condensation and mould.
Comfort and health come first. The Energy Saving Trust notes that older people, anyone with a health condition and people at home for long periods may need a higher minimum temperature. If someone is in all day, heating the occupied rooms all day is simply heating when needed. Any adjustment inside a gas boiler must be made by a Gas Safe registered engineer.
So is it cheaper to leave heating on all day in your home?
Use this rule: for a boiler or electric heaters, heat the home when people are in and let it cool when they are not; for a heat pump, keep it running with a set-back. The more heat your home loses, the more switching off a boiler saves. Comparing fuels as well? Our guide to the cheapest way to heat a house in the UK costs each option per kWh of heat, and the average gas usage UK figures let you benchmark your bill.
Frequently Asked Questions
Is it cheaper to leave the heating on low all day?
Not with a gas or oil boiler. A home kept warm all day loses heat for every hour of it, while a home allowed to cool loses less. The Energy Saving Trust says keeping a boiler on all the time uses more energy and costs more money.
Does reheating a cold house use more energy than leaving the heating on?
No. The reheat only replaces the heat that escaped while the heating was off, and a cooler house loses heat more slowly. Over a full day the total heat supplied is lower when the home spends some hours at a lower temperature.
Should I leave my heat pump on all the time?
Usually yes. The Energy Saving Trust says it is best to keep a heat pump on all the time and use a lower set-back temperature when you are out or asleep, because it runs more efficiently over longer periods at lower water temperatures.
What temperature should the heating be set to when I am out?
With a programmable thermostat the Energy Saving Trust suggests a set-back of about 12°C to 15°C when you are out or asleep. With a boiler you can also switch the heating off while nobody is in.
Can switching heating off cause damp?
A home left very cold for long periods is more prone to condensation. The Energy Saving Trust advises keeping some background heat in rooms to reduce condensation and mould risk. A set-back temperature gives that while still saving energy.
Checked October 2026 by the Solaxyra Editorial Team. Sources: Energy Saving Trust: when should I put my heating on?, Energy Saving Trust: thermostats and heating controls, Energy Saving Trust: how to ensure a heat pump runs efficiently, Ofgem: energy price cap 1 October to 31 December 2026, Wikipedia: thermal transmittance.