How to Repressurise a Boiler: Step-by-Step

This guide explains how to repressurise a boiler on a sealed central heating system, the type used with most combi and system boilers. It covers the right pressure, how to use a filling loop or a key-type filler, and what it means if the pressure keeps falling.

Quick answer: With the heating off and the system cold, open the filling loop valves slowly and watch the boiler gauge rise to the level in your manual, usually 1 to 1.5 bar. Close both valves fully, then reset the boiler if it shows a fault. If the pressure keeps dropping, call a Gas Safe registered engineer.

How to repressurise a boiler: open filling loop, fill to 1 to 1.5 bar, close valves

What should boiler pressure be?

Most combi and system boilers should read around 1 to 1.5 bar when the system is cold, rising a little when the heating is on. Your boiler manual gives the exact figure, and many gauges have a green band. Below about 0.5 to 0.8 bar many boilers lock out and show a low pressure fault.

Why does boiler pressure drop?

  • Bleeding radiators, which lets out some water with the air.
  • A small leak from a radiator valve, pipe joint or the boiler.
  • A faulty pressure relief valve letting water out through the pipe outside.
  • A failed expansion vessel, which makes the pressure rise when hot and fall when cold.

What you need

  • Your boiler manual, or the model number to look it up.
  • Access to the filling loop: a flexible silver hose with valves under the boiler, a built-in lever, or a removable key on some models.

How to repressurise a boiler step by step

  1. Turn the heating off and let the system cool. Pressure readings are higher when hot.
  2. Find the filling loop. If it is a removable hose, connect both ends securely.
  3. Open the first valve, then slowly open the second. You will hear water flowing.
  4. Watch the pressure gauge. Stop when it reaches the level in your manual, usually 1 to 1.5 bar.
  5. Close both valves fully, the second one first.
  6. If your filling loop is removable, disconnect it, catching any drips. Leaving it connected can let pressure creep up.
  7. Reset the boiler if it shows a fault code, following the manual.
  8. Turn the heating on and check the pressure stays steady.

What if the pressure is too high?

If the gauge reads above about 2.5 bar, the filling loop may not be fully closed, or the expansion vessel may have lost its charge. You can lower it by bleeding a radiator to let out a little water. If it rises again, ask an engineer to check the system.

When should you call an engineer?

If you have to top up more than once every few months, there is probably a leak or a fault. A Gas Safe registered engineer can find leaks, recharge or replace the expansion vessel and check the pressure relief valve. Never open the boiler casing yourself.

Does low pressure affect running costs?

A boiler that keeps locking out wastes time rather than gas, but trapped air and poor circulation make radiators heat unevenly, so the boiler runs longer to reach the thermostat temperature. Keeping the system at the right pressure and bleeding radiators each autumn helps it run efficiently.

Frequently Asked Questions

What should my boiler pressure be?

Usually 1 to 1.5 bar when cold; check your manual.

Is it safe to repressurise a boiler myself?

Yes, using the filling loop as described in your manual. Do not open the boiler itself.

Why does my boiler keep losing pressure?

Usually a leak, a faulty pressure relief valve or a failed expansion vessel.

Should the filling loop be left connected?

Removable loops should be disconnected after use; valves should always be closed.

Checked November 2026 by the Solaxyra Editorial Team. Sources: Gas Safe Register: Gas safety advice, Energy Saving Trust: Boilers.