This single phase power calculator works out the real power in kW, the apparent power in kVA and the reactive power from the voltage, current and power factor of a single-phase supply. It also shows the energy and cost per hour at that load.
Quick answer: Real power is volts times amps times power factor: P = V ร I ร PF. A 13 A load on 230 V with a power factor of 1 is 2,990 W, about 3 kW, which costs about 79p an hour at 26.32p per kWh.

What Is a Single Phase Power Calculator?
A single phase power calculator applies the basic AC power formula to a single-phase supply, the type used in nearly all UK and European homes. It separates real power, which does useful work and appears on your bill, from apparent power, which sets the current cables and fuses must carry.
How Do You Use the Single Phase Power Calculator?
- Enter the supply voltage, normally 230 V.
- Enter the current from a clamp meter or the appliance rating.
- Enter the power factor. Use 1 for resistive loads such as heaters, kettles and immersion heaters.
- Check the price per kWh to see the hourly cost.

Single Phase Power Table at 230 V
| Current | Power at PF 1 | Power at PF 0.9 | Cost per hour at PF 1 |
|---|---|---|---|
| 3 A | 690 W | 621 W | 18.2p |
| 6 A | 1,380 W | 1,242 W | 36.3p |
| 10 A | 2,300 W | 2,070 W | 60.5p |
| 13 A | 2,990 W | 2,691 W | 78.7p |
| 32 A | 7,360 W | 6,624 W | ยฃ1.94 |
| 60 A | 13,800 W | 12,420 W | ยฃ3.63 |
How Much Power Can a Single Phase Supply Provide?
Most UK homes have a single-phase supply protected by a main fuse of 60, 80 or 100 A. At 230 V, 100 A is about 23 kW. Adding a heat pump, an EV charger and an electric shower can push peak demand close to that, which is why maximum demand checks matter before new loads are added.
Single Phase or Three Phase?
Three-phase supplies deliver power over three conductors and are common in commercial buildings and some larger homes. For the same current per phase, three phase delivers about three times the power. Use our three phase power calculator for those supplies.
Worked Example: Checking a Workshop Circuit
Example: a woodworker in Stoke measures 9.5 A on a table saw circuit with a power factor of about 0.85.
- Apparent power = 230 ร 9.5 = 2,185 VA.
- Real power = 2,185 ร 0.85 = 1,857 W.
- Cost per hour = 1.857 kWh ร 26.32p = 48.9p.
Frequently Asked Questions
What is the formula for single phase power?
P = V ร I ร PF, in watts.
How many kW is 13 amps at 230 V?
About 2.99 kW at a power factor of 1.
What is the difference between kW and kVA?
kW is real power; kVA is apparent power. They are equal when the power factor is 1.
How many kW can a 100 A single phase supply handle?
About 23 kW at 230 V, though diversity and the supplier’s rules apply.