Single Phase Power Calculator

UK and EU nominal: 230 V
1 for heaters and kettles
UK price cap, Oct to Dec 2026: 26.32p. Change to your tariff
Real power
n/a
Apparent powern/a
Reactive powern/a
Energy per hour at this loadn/a
Cost per hour at your pricen/a
Formula and breakdown

n/a

n/a

n/a

This single phase power calculator works out the real power in kW, the apparent power in kVA and the reactive power from the voltage, current and power factor of a single-phase supply. It also shows the energy and cost per hour at that load.

Quick answer: Real power is volts times amps times power factor: P = V ร— I ร— PF. A 13 A load on 230 V with a power factor of 1 is 2,990 W, about 3 kW, which costs about 79p an hour at 26.32p per kWh.

Single phase power formula: 230 volts times 13 amps equals 2.99 kilowatts

What Is a Single Phase Power Calculator?

A single phase power calculator applies the basic AC power formula to a single-phase supply, the type used in nearly all UK and European homes. It separates real power, which does useful work and appears on your bill, from apparent power, which sets the current cables and fuses must carry.

How Do You Use the Single Phase Power Calculator?

  1. Enter the supply voltage, normally 230 V.
  2. Enter the current from a clamp meter or the appliance rating.
  3. Enter the power factor. Use 1 for resistive loads such as heaters, kettles and immersion heaters.
  4. Check the price per kWh to see the hourly cost.
Single Phase Power Calculator with example inputs filled in and the results panel

Single Phase Power Table at 230 V

CurrentPower at PF 1Power at PF 0.9Cost per hour at PF 1
3 A690 W621 W18.2p
6 A1,380 W1,242 W36.3p
10 A2,300 W2,070 W60.5p
13 A2,990 W2,691 W78.7p
32 A7,360 W6,624 Wยฃ1.94
60 A13,800 W12,420 Wยฃ3.63

How Much Power Can a Single Phase Supply Provide?

Most UK homes have a single-phase supply protected by a main fuse of 60, 80 or 100 A. At 230 V, 100 A is about 23 kW. Adding a heat pump, an EV charger and an electric shower can push peak demand close to that, which is why maximum demand checks matter before new loads are added.

Single Phase or Three Phase?

Three-phase supplies deliver power over three conductors and are common in commercial buildings and some larger homes. For the same current per phase, three phase delivers about three times the power. Use our three phase power calculator for those supplies.

Worked Example: Checking a Workshop Circuit

Example: a woodworker in Stoke measures 9.5 A on a table saw circuit with a power factor of about 0.85.

  1. Apparent power = 230 ร— 9.5 = 2,185 VA.
  2. Real power = 2,185 ร— 0.85 = 1,857 W.
  3. Cost per hour = 1.857 kWh ร— 26.32p = 48.9p.

Frequently Asked Questions

What is the formula for single phase power?

P = V ร— I ร— PF, in watts.

How many kW is 13 amps at 230 V?

About 2.99 kW at a power factor of 1.

What is the difference between kW and kVA?

kW is real power; kVA is apparent power. They are equal when the power factor is 1.

How many kW can a 100 A single phase supply handle?

About 23 kW at 230 V, though diversity and the supplier’s rules apply.

Checked November 2026 by the Solaxyra Editorial Team. Sources: Ofgem: Energy price cap, 1 October to 31 December 2026.